UL 1007
UL 1007 hook-up wire combines a copper conductor with PVC for internal appliance wiring and compact electronic assemblies. The base AWM style is identified for 300V and 80°C service, with additional product markings evaluated separately. The insulated conductor supports organized routing and color identification within the equipment assembly. Gauge, stranding and color options allow equipment builders to match the wire to their circuit and termination requirements. This family serves OEM production, harness assembly and maintenance work where the specified appliance wiring construction is required.
Available Sizes
8 sizes in stock, cut to length. Click a size to start your quote.
Construction & Ratings
Conductor
Insulation
Voltage Rating
Temperature Rating
Available Insulation Colors
20 color options in stock. Custom striping and ID print available on request.
Listings & Standards
UL 1007 Part Numbers
179 UL 1007 part numbers stocked or sourced by Mid America Wire & Cable. Open a part number for its details, or request a quote for the size and length you need.
| Part Number | Description | Unit Weight (lbs) |
|---|---|---|
| 80B-1265-54 | 12(65) UL1007 Tinned Copper 300V Green with Yellow Stripe | 0.02 |
| 80B-1441-0 | 14(41) UL1007 Tinned Copper 300V Black | 0.02 |
| 80B-1441-09 | 14(41) UL1007 Tinned Copper 300V White | 0.02 |
| 80B-1441-11/12 | 14(41) UL1007 Tinned Copper Tan Twisted with Pink | 0.02 |
| 80B-1441-54 | 14(41) UL1007 Tinned Copper 300V Green with Yellow Stripe | 0.02 |
| 80B-1441-9/11 | 14(41) UL1007 Tinned Copper 300 Volt White Twsited with Tan | 0.02 |
| 80B-1626-0 | 16(26) UL1007 Tinned Copper 300 Volt Black | 0.02 |
| 80B-1626-01 | 16(26) UL1007 Tinned Copper 300 Volt Brown | 0.02 |
| 80B-1626-02 | 16(26) UL1007 Tinned Copper 300 Volt Red | 0.02 |
| 80B-1626-04 | 16(26) UL1007 Tinned Copper 300 Volt Yellow | 0.02 |
| 80B-1626-05 | 16(26) UL1007 Tinned Copper Green | 0.02 |
| 80B-1626-06 | 16(26) UL1007 Tinned Copper 300 Volt Blue | 0.02 |
| 80B-1626-09 | 16(26) UL1007 Tinned Copper 300 Volt White | 0.02 |
| 80B-1626-12 | 16(26) UL1007 tinned Copper 300 volt Pink | 0.02 |
| 80B-1626-19 | 16(26) UL1007 Tinned Copper 300 Volt | 0.02 |
| 80B-1626-191T | 16(26)-2/c UL1007 Tinned Copper | 0.03 |
| 80B-1626-91 | 16(26) UL1007 tinned Copper 300 Volt White with Brown Stripe | 0.02 |
| 80B-1626-91T | 16(26)-2/c UL1007 Tinned Copper | 0.03 |
| 80B-1626-93 | 16(26) UL1007 Tinned Copper 300 Volt White with Orange Stripe | 0.02 |
| 80B-1626-96 | 16(26) UL1007 Tinned Copper 300 Volt White with Blue Stripe | 0.02 |
| 80B-1626-96T | 16(26)-2/c UL1007 Tinned Copper | 0.02 |
| 80B-1800-0 | 18 Solid UL1007/1569 Tinned Copper 300 Volt Black | 0.01 |
| 80B-1800-01 | 18 Solid UL1007/1569 Tinned Copper 300 Volt Brown | 0.01 |
| 80B-1800-02 | 18 Solid UL1007/1569 Tinned Copper 300 Volt Red | 0.01 |
| 80B-1800-03 | 18 Solid UL1007/1569 Tinned Copper 300 Volt Orange | 0.01 |
| 80B-1800-04 | 18 Solid UL1007/1569 Tinned Copper 300 Volt Yellow | 0.01 |
| 80B-1800-05 | 18 Solid UL1007/1569 Tinned Copper 300 Volt Green | 0.01 |
| 80B-1800-06 | 18 Solid UL 1007/1569 Tinned Copper 300 Volt Blue | 0.01 |
| 80B-1800-07 | 18 Solid UL1007/1569 Tinned Copper 300 Volt Purple | 0.01 |
| 80B-1800-09 | 18 Solid UL1007/1569 Tinned Copper 300 Volt White | 0.01 |
| 80B-1816-0 | 18(16) UL1007 Tinned Copper Black | 0.01 |
| 80B-1816-009 | 18(16) UL1007 Tinned Copper Black with White Stripe | 0.01 |
| 80B-1816-01 | 18(16) UL1007 Tinned Copper Brown | 0.01 |
| 80B-1816-02 | 18(16) UL1007 Tinned Copper Red | 0.01 |
| 80B-1816-03 | 18(16) UL1007 Tinned Copper 300 Volt Orange | 0.01 |
| 80B-1816-04 | 18(16) UL1007 Tinned Copper Yellow | 0.01 |
| 80B-1816-05 | 18(16) Ul1007 Tinned Copper Green | 0.01 |
| 80B-1816-06 | 18(16) UL1007 Tinned Copper Blue | 0.01 |
| 80B-1816-07 | 18(16) UL1007 Tinned Copper Purple | 0.01 |
| 80B-1816-08 | 18(16) Ul1007 Tinned Copper 300 Volt Gray | 0.01 |
| 80B-1816-09 | 18(16) UL1007 Tinned Copper White | 0.01 |
| 80B-1816-0909T | 18(16) UL1007 Tinned Copper White Twisted with White ( 1 Twist per Inch) | 0.01 |
| 80B-1816-11 | 18(16) UL1007 Tinned Copper 300 Volt Tan | 0.01 |
| 80B-1816-12 | 18(16) UL1007 Tinned Copper 300 Volt Pink | |
| 80B-1816-191T | 18(16) -2/c UL1007 Tinned Copper 300 Volt Brown and White with Brown Stripe Twisted ( 2 Twist per Inch) | 0.01 |
| 80B-1816-19T | 18(16)-2/c UL1007 Tinned Copper 300 Volt Brown and White Twisted (2-twist per Inch) | 0.01 |
| 80B-1816-20 | 18(16) UL1007 Tinned Copper Red with Black Stripe | 0.01 |
| 80B-1816-29 | 18(16) UL1007 Tinned Copper Red with White Stripe | 0.01 |
| 80B-1816-30 | 18(16) UL1007 Tinned Copper Orange with Black Stripe | 0.01 |
| 80B-1816-39 | 18(16) UL1007 Tinned Copper 300 Volt Orange with White Stripe | 0.01 |
| 80B-1816-3937T | 18(16)-3/c UL1007 Tinned Copper | 0.01 |
| 80B-1816-40 | 18(16) UL1007 Tinned Copper Yellow with Black Stripe | 0.01 |
| 80B-1816-49 | 18(16) UL1007 Tinned Copper 300 VoltYellow with White Stripe | 0.01 |
| 80B-1816-50 | 18(16) UL1007 Tinned Copper Green with Black Stripe | 0.01 |
| 80B-1816-54 | 18(16) UL1007 Tinned Copper Green with Yellow Stripe | 0.01 |
| 80B-1816-59 | 18(16) UL1007 Tinned Copper Green with White Stripe | 0.01 |
| 80B-1816-60 | 18(16) UL 1007 Tinned Copper Blue with Black Stripe | 0.01 |
| 80B-1816-69 | 18(16) UL1007 Tinned Copper 300 Volt Blue with White Stripe | 0.01 |
| 80B-1816-898T | 18(16)-2/c UL1007 Tinned Copper | 0.01 |
| 80B-1816-90 | 18(16) UL1007 Tinned Copper White with Black Stripe | 0.01 |
| 80B-1816-91 | 18(16) UL1007 Tinned Copper 300 Volt White with Brown Stripe | 0.01 |
| 80B-1816-92 | 18 (16) UL1007 Tinned Copper White with Red Stripe | 0.01 |
| 80B-1816-93 | 18(16) Ul1007 Tinned Copper 300 Volt White with Orange Stripe | 0.01 |
| 80B-1816-94 | 18(16) UL1007 Tinned Copper White with Yellow Stripe | 0.01 |
| 80B-1816-96 | 18(16) UL1007 Tinned Copper 300 Volt White with Blue Stripe | 0.01 |
| 80B-1841-0 | 18(41) UL1007 Tinned Copper Black | 0.01 |
| 80B-1841-0-BC | 18(41) UL1007 Bare Copper 300 Volt Black | 0.01 |
| 80B-1841-04 | 18(41) UL1007 Tinned Copper Yellow | 0.01 |
| 80B-1841-06 | 18(41) UL1007 Tinned Copper Blue | 0.01 |
| 80B-2010-0 | 20(10) UL1007/1569 Tinned Copper 300 Volt Black | 0.01 |
| 80B-2010-002 | 20(10) UL1007/1569 Tined Copper 300 Volt Black with Red Stripe | 0.01 |
| 80B-2010-009T | 20(10) UL1007/1569 Tinned Copper 300 Volt Black and White Twisted | 0.01 |
| 80B-2010-01 | 20(10) UL1007/1569 Tinned Copper 300 Volt Brown | 0.01 |
| 80B-2010-02 | 20(10) UL1007/1569 Tinned Copper 300 Volt Red | 0.01 |
| 80B-2010-03 | 20(10) UL1007/1569 Tinned 300 Volt Copper Orange | 0.01 |
| 80B-2010-04 | 20(10) UL1007/1569 Tinned Copper 300 Volt Yellow | 0.01 |
| 80B-2010-05 | 20(10) UL1007/1569 Tinned Copper 300 Volt Green | 0.01 |
| 80B-2010-06 | 20(10) UL1007/1569 Tinned Copper 300 Volt Blue | 0.01 |
| 80B-2010-06L | 20(10) UL1007/1569 Tinned Copper 300 Volt Light Blue | 0.01 |
| 80B-2010-07 | 20(10) UL1007/1569 Tinned Copper 300 Volt Purple | 0.01 |
| 80B-2010-08 | 20(10 UL1007/1569 Tinned Copper 300 Volt Gray | 0.01 |
| 80B-2010-09 | 20(10) UL1007/1569 Tinned Copper 300 Volt White | 0.01 |
| 80B-2010-0TOPCOAT | 20(10) UL1007/1569 Tinned Copper 300 Volt Black TOPCOAT | 0.01 |
| 80B-2010-11 | 20(10) UL1007/1569 Tinned Copper 300 Volt Tan | 0.01 |
| 80B-2010-12 | 20(10) UL1007/1569 Tinned Copper 300 Volt Pink | 0.01 |
| 80B-2010-20T | 20(10) UL1007/1569 Tinned Copper 300 Volt Red and Black Twisted (2 Twist per Inch | 0.01 |
| 80B-2010-3937T | 20(10)-3/c UL1007 Tinned Copper | 0.01 |
| 80B-2010-54 | 20(10) UL1007 Tinned Copper 300 Volt Green with Yellow Stripe | 0.01 |
| 80B-2200-0 | 22 Solid Ul1007 Tinned Copper 300 Volt Black | |
| 80B-2207-0 | 22 (7) UL1007 Tinned Copper 300 Volt Black | |
| 80B-2207-0/2T | 22(7)-2/c UL1007 Tinned Copper | 0.01 |
| 80B-2207-0/3T | 22(7)-2/c UL1007 Tinned Copper | 0.01 |
| 80B-2207-0/4/5T | 22(7)-3/c UL1007 Tinned Copper | 0.01 |
| 80B-2207-0/6T | 22(7)-2/c UL1007 Tinned Copper | 0.01 |
| 80B-2207-0/9T | 22(7)-2/c UL1007 Tinned Copper | 0.01 |
| 80B-2207-004 | 22(7) Ul1007 Tinned Copper 300 Volt Black with Yellow Stripe | |
| 80B-2207-009 | 22(7) Ul1007 Tinned Copper 3000 Volt Black with White Stripe | |
| 80B-2207-01 | 22(7) UL1007 Tinned Copper 300 Volt Brown | |
| 80B-2207-02 | 22(7) UL1007 Tinned Copper 300 Volt Red | |
| 80B-2207-029T | 22(7)-3/c UL1007 Tinned Copper | 0.01 |
| 80B-2207-03 | 22(7) UL1007 Tinned Copper 300 Volt Orange | |
| 80B-2207-04 | 22 (7) UL1007 Tinned Copper 300 Volt Yellow P/N PI240053 | |
| 80B-2207-05 | 22(7) UL1007 Tinned Copper 300 Volt Green | |
| 80B-2207-06 | 22(7) UL1007 Tinned Copper 300 Volt Blue | |
| 80B-2207-07 | 22(7) UL1007 Tinned Copper 300 Volt Purple | |
| 80B-2207-08 | 22(7) UL1007 Tinned Copper 300 Volt Gray | |
| 80B-2207-09 | 22(7) UL1007 Tinned Copper 300 Volt White | |
| 80B-2207-11 | 22(7) UL1007 Tinned Copper 300 Volt Tan | |
| 80B-2207-12 | 22(7) UL1007 Tinned Copper 300 Volt Pink | |
| 80B-2207-191T | 22(7)-2/c UL1007 tinned Copper | 0.01 |
| 80B-2207-3937T | 22(7)-3/c UL1007 Tinned Copper | 0.01 |
| 80B-2207-393T | 22(7)-2/c UL1007 Tinned Copper | 0.01 |
| 80B-2207-40 | 22(7) UL1007 Tinned Copper 300 Volt Yellow with Black Stripe | |
| 80B-2207-41 | 22(7) UL1007 Tinned Copper 300 Volt Yellow with Brown Stripe | |
| 80B-2207-42 | 22(7) Ul1007 Tinned Copper 300 Volt Yellow with Red Stripe | |
| 80B-2207-43 | 22(7) Ul1007 Tinned Copper 300 Volt Yellow with Orange Stripe | |
| 80B-2207-45 | 22(7) UL1007 Tinned Copper 300 Volt Yellow with Green Stripe | |
| 80B-2207-46 | 22(7) Ul1007 Tinned Copper 300 Volt Yellow with Blue Stripe | |
| 80B-2207-47 | 22(7) Ul1007 Tinned Copper 300 Volt Yellow with Purple Stripe | |
| 80B-2207-48 | 22(7) Ul1007 Tinned Copper 300 Volt Yellow with Gray Stripe |
Showing 120 of 179. See all UL 1007 part numbers
UL 1007 Questions and Answers
What is UL 1007 wire rated for?
300V and -40°C to 80°C. UL 1007 is a UL 758 appliance wiring material (AWM style 1007) with PVC insulation at a nominal 0.016 inch wall and a VW-1 flame rating.
What gauges does UL 1007 come in?
30 AWG to 16 AWG, with bare or tinned copper, solid or stranded.
What is UL 1007 wire used for?
The low-voltage side of equipment: electronics and PCB-to-chassis wiring, LED lighting and signage, instrumentation and sensor runs, and control panel wiring under 300V. It is not for line voltage (120V, 240V or 480V) or for hot cabinets.
What is the difference between UL 1007 and UL 1015?
UL 1007 is 300V and 80°C with a thin wall; UL 1015 is 600V and 105°C with a heavy wall. On a 16 AWG conductor, UL 1007 has roughly half the insulation thickness. See UL 1007 vs UL 1015.
When should I step up from UL 1007?
When the circuit is above 300V, or when ambient plus temperature rise inside the enclosure crowds 80°C. Step up to UL 1015 (105°C) or an XLPE style such as UL 3266 (125°C).
Something else? Call (918) 622-1489 or send us the size and length you need.